Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Intervalo de año de publicación
1.
Acta Ortop Bras ; 31(spe3): e266948, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37720810

RESUMEN

Introduction: Metacarpal fractures are common and can be treated surgically using Kirschner wires (K-wires) or intramedullary fixation with compression screws (IMCS). Objectives: Analyze the postsurgical results from treating the metacarpal extra-articular fractures through the retrograde Kirschner wire technique, and compare it with the intramedullary compression screw fixation. Methods: Retrospective and quantitative studies were to analyze patients' medical records, and a postsurgical evaluation questionnaire was given to the patients, who were divided into K-wire and IMCS. Results: The period of immobilization with a splint took six weeks for the K-wire group and four weeks for the IMCS group. The average time for consolidation took, respectively, fifty-seven days and forty-seven days. The first group could restart their activities twenty-two days after the other, and the average force value of the treated hand, when compared with its contralateral, was 93.9% and 95.4%, respectively. Between the operated hand and its contralateral, there was a difference of 16° in the total measures of the metacarpophalangeal and interphalangeal joint's range of movement among the K-wire group and 5° among the IMCS group. Conclusion: The patients who participated in this study showed excellent results after surgery, and both treatments were proven to be safe and reliable. Evidence level III; Retrospective comparative study .


Introdução: Fraturas dos metacarpos são frequentes e podem ser tratadas de forma cirúrgica com os fios de Kirschner (FK) e Fixação Intramedular com Parafuso de Compressão (FIPC). Objetivo: Analisar os resultados pós-operatórios do tratamento das fraturas extra-articulares dos metacarpos pela técnica retrógrada com fios de Kirschner e comparar com a fixação intramedular utilizando parafuso de compressão. Métodos: Estudo retrospectivo, quantitativo, com análise de prontuários, utilizando questionários de avaliação pós-operatória em dez pacientes divididos em dois grupos: FIPC e FK. Resultados: O período de imobilização com tala nos grupos FK e FIPC foram de seis e quatro semanas respectivamente, já o tempo médio para consolidação foi de 57 e 47 dias respectivamente. O grupo FK retornou as atividades laborais após os FIPC. O valor médio de força na mão acometida comparada a contralateral foi de 93,9% no grupo FK, e no FIPC de 95,4%. Medidas da soma de amplitude de movimento das articulações metacarpofalangeanas e interfalangeanas no grupo FK obtiveram diferença média entre as mãos operada e a contralateral de 16°, já na FIPC observou-se 5°. Conclusão: Os pacientes estudados apresentaram excelentes resultados pós-operatórios e ambos os tratamentos provam ser seguros e confiáveis. Nível de evidência III; Estudo retrospectivo comparativo .

2.
Acta Ortop Bras ; 31(4): e266635, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547237

RESUMEN

Currently, the market offers a wide variety of suture threads, made of materials with different structural and chemical properties. Among many other characteristics, they vary in origin, absorption or degradation, and structure. From this variety, the clinical doubt arises as to which material provides the patient with the best healing quality. Objective: This study aims to comparatively evaluate two different types of suture threads-Monocryl® (polyglycaprone 25) and Ethilon® (nylon)-regarding their ability to aid in tissue regeneration by a histological and immunohistochemical analysis of the skin of rats sutured with the aforementioned materials. Methods: This basic experimental study used 12 adult Wistar rats, randomly divided into three groups with four animals each and subjected to four longitudinal incisions under anesthesia. Each group corresponded to a postsurgical evaluation date (one, seven, and 14 days). Results: At 14 postoperative days, the studied groups had no histological difference. However, the use of nylon thread showed greater evidence of earlier fibrotic union. Conclusion: This study found no histological difference in healing 14 days after surgery among the techniques and the types of suture threads. Level of Evidence II, Therapeutic Studies.


Atualmente, encontra-se disponível no mercado uma grande variedade de fios de sutura, compostos de materiais com diferentes propriedades estruturais e químicas, que variam quanto à origem, absorção ou degradação e estrutura, entre outras características. A partir dessa disponibilidade, emerge a dúvida clínica quanto ao material que propicia a melhor qualidade de cicatrização ao paciente. Objetivo: Avaliar comparativamente dois tipos de fios - Monocryl® (poliglicaprone 25) e Ethilon® (nylon) - quanto à sua capacidade de auxílio na regeneração tecidual, por meio da análise histológica e imuno-histoquímica da pele de ratos submetidos a suturas com esses materiais. Métodos: Neste estudo básico experimental, foram utilizados 12 ratos adultos da linhagem Wistar, randomicamente divididos em três grupos com quatros animais cada, que foram submetidos a quatro incisões longitudinais sob anestesia. Cada grupo correspondeu a uma data de avaliação pós-cirúrgica (1, 7 e 14 dias). Resultados: Passados 14 dias após a operação, não houve diferença histológica em relação aos grupos estudados. No entanto, o uso de fio de nylon apresentou evidência de união fibrótica mais precoce. Conclusão: Não há diferença histológica de cicatrização após 14 dias pós-operatórios entre as técnicas e os tipos de fio de sutura. Nível de Evidência II, Estudos Terapêuticos.

3.
Acta ortop. bras ; 31(4): e266635, 2023. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447094

RESUMEN

ABSTRACT Currently, the market offers a wide variety of suture threads, made of materials with different structural and chemical properties. Among many other characteristics, they vary in origin, absorption or degradation, and structure. From this variety, the clinical doubt arises as to which material provides the patient with the best healing quality. Objective: This study aims to comparatively evaluate two different types of suture threads-Monocryl® (polyglycaprone 25) and Ethilon® (nylon)-regarding their ability to aid in tissue regeneration by a histological and immunohistochemical analysis of the skin of rats sutured with the aforementioned materials. Methods: This basic experimental study used 12 adult Wistar rats, randomly divided into three groups with four animals each and subjected to four longitudinal incisions under anesthesia. Each group corresponded to a postsurgical evaluation date (one, seven, and 14 days). Results: At 14 postoperative days, the studied groups had no histological difference. However, the use of nylon thread showed greater evidence of earlier fibrotic union. Conclusion: This study found no histological difference in healing 14 days after surgery among the techniques and the types of suture threads. Level of Evidence II, Therapeutic Studies.


RESUMO Atualmente, encontra-se disponível no mercado uma grande variedade de fios de sutura, compostos de materiais com diferentes propriedades estruturais e químicas, que variam quanto à origem, absorção ou degradação e estrutura, entre outras características. A partir dessa disponibilidade, emerge a dúvida clínica quanto ao material que propicia a melhor qualidade de cicatrização ao paciente. Objetivo: Avaliar comparativamente dois tipos de fios - Monocryl ® (poliglicaprone 25) e Ethilon ® (nylon) - quanto à sua capacidade de auxílio na regeneração tecidual, por meio da análise histológica e imuno-histoquímica da pele de ratos submetidos a suturas com esses materiais. Métodos: Neste estudo básico experimental, foram utilizados 12 ratos adultos da linhagem Wistar, randomicamente divididos em três grupos com quatros animais cada, que foram submetidos a quatro incisões longitudinais sob anestesia. Cada grupo correspondeu a uma data de avaliação pós-cirúrgica (1, 7 e 14 dias). Resultados: Passados 14 dias após a operação, não houve diferença histológica em relação aos grupos estudados. No entanto, o uso de fio de nylon apresentou evidência de união fibrótica mais precoce. Conclusão: Não há diferença histológica de cicatrização após 14 dias pós-operatórios entre as técnicas e os tipos de fio de sutura. Nível de Evidência II, Estudos Terapêuticos.

4.
Acta ortop. bras ; 31(spe3): e266948, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1505501

RESUMEN

ABSTRACT Introduction: Metacarpal fractures are common and can be treated surgically using Kirschner wires (K-wires) or intramedullary fixation with compression screws (IMCS). Objectives: Analyze the postsurgical results from treating the metacarpal extra-articular fractures through the retrograde Kirschner wire technique, and compare it with the intramedullary compression screw fixation. Methods: Retrospective and quantitative studies were to analyze patients' medical records, and a postsurgical evaluation questionnaire was given to the patients, who were divided into K-wire and IMCS. Results: The period of immobilization with a splint took six weeks for the K-wire group and four weeks for the IMCS group. The average time for consolidation took, respectively, fifty-seven days and forty-seven days. The first group could restart their activities twenty-two days after the other, and the average force value of the treated hand, when compared with its contralateral, was 93.9% and 95.4%, respectively. Between the operated hand and its contralateral, there was a difference of 16° in the total measures of the metacarpophalangeal and interphalangeal joint's range of movement among the K-wire group and 5° among the IMCS group. Conclusion: The patients who participated in this study showed excellent results after surgery, and both treatments were proven to be safe and reliable. Evidence level III; Retrospective comparative study .


RESUMO Introdução: Fraturas dos metacarpos são frequentes e podem ser tratadas de forma cirúrgica com os fios de Kirschner (FK) e Fixação Intramedular com Parafuso de Compressão (FIPC). Objetivo: Analisar os resultados pós-operatórios do tratamento das fraturas extra-articulares dos metacarpos pela técnica retrógrada com fios de Kirschner e comparar com a fixação intramedular utilizando parafuso de compressão. Métodos: Estudo retrospectivo, quantitativo, com análise de prontuários, utilizando questionários de avaliação pós-operatória em dez pacientes divididos em dois grupos: FIPC e FK. Resultados: O período de imobilização com tala nos grupos FK e FIPC foram de seis e quatro semanas respectivamente, já o tempo médio para consolidação foi de 57 e 47 dias respectivamente. O grupo FK retornou as atividades laborais após os FIPC. O valor médio de força na mão acometida comparada a contralateral foi de 93,9% no grupo FK, e no FIPC de 95,4%. Medidas da soma de amplitude de movimento das articulações metacarpofalangeanas e interfalangeanas no grupo FK obtiveram diferença média entre as mãos operada e a contralateral de 16°, já na FIPC observou-se 5°. Conclusão: Os pacientes estudados apresentaram excelentes resultados pós-operatórios e ambos os tratamentos provam ser seguros e confiáveis. Nível de evidência III; Estudo retrospectivo comparativo .

5.
Acta Ortop Bras ; 29(5): 274-276, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34629953

RESUMEN

OBJECTIVE: Evaluate the experience of private and public health services with the WALANT procedure in the COVID-19 pandemic. METHODS: This is a retrospective, multicenter longitudinal study gathering cases of hand surgery subjected to the WALANT technique in the Hospitals Dr. Radamés Nardini and IFOR during the COVID-19 pandemic (August 2020). As a parameter, the verbal numerical rating scale for twenty patients referring to the preoperative, intraoperative and postoperative periods was applied. RESULTS: The patients did not feel any pain during surgery, which showed the efficiency of the anesthetic technique in its purpose. CONCLUSION: The results indicate the WALANT technique as beneficial when facing the COVID-19 pandemic, as the main differential of the technique is that it is applied by a well-trained orthopedic hand surgeon. Level of Evidence IV, Case Series.


OBJECTIVE: Avaliar a experiência dos serviços privado e público de saúde com o procedimento WALANT frente à pandemia COVID-19. MÉTODOS: Trata-se de um estudo longitudinal retrospectivo, multicêntrico, de casos de cirurgia de mão submetidos à técnica WALANT nos hospitais Dr. Radamés Nardini e IFOR, durante a pandemia da COVID-19, em agosto de 2020. Como parâmetro, foi aplicada a Escala Verbal de Dor para 20 pacientes referente ao pré-operatório, intra-operatório e no pós-operatório. RESULTADOS: Os pacientes não sentiram nenhuma dor durante a cirurgia, tendo a técnica anestésica de mostrado eficaz. CONCLUSÃO: Pelas análises, foi possível considerar segura e benéfica a técnica WALANT diante da pandemia da COVID-19, que apresenta o diferencial de ser aplicada por um cirurgião ortopédico especialista em mão bem treinado. Nível de Evidência IV, Série de Casos.

6.
Acta ortop. bras ; 29(5): 274-276, Sept.-Oct. 2021. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1339066

RESUMEN

ABSTRACT Objective: Evaluate the experience of private and public health services with the WALANT procedure in the COVID-19 pandemic. Methods: This is a retrospective, multicenter longitudinal study gathering cases of hand surgery subjected to the WALANT technique in the Hospitals Dr. Radamés Nardini and IFOR during the COVID-19 pandemic (August 2020). As a parameter, the verbal numerical rating scale for twenty patients referring to the preoperative, intraoperative and postoperative periods was applied. Results: The patients did not feel any pain during surgery, which showed the efficiency of the anesthetic technique in its purpose. Conclusion: The results indicate the WALANT technique as beneficial when facing the COVID-19 pandemic, as the main differential of the technique is that it is applied by a well-trained orthopedic hand surgeon. Level of Evidence IV, Case Series.


RESUMO Objective: Avaliar a experiência dos serviços privado e público de saúde com o procedimento WALANT frente à pandemia COVID-19. Métodos: Trata-se de um estudo longitudinal retrospectivo, multicêntrico, de casos de cirurgia de mão submetidos à técnica WALANT nos hospitais Dr. Radamés Nardini e IFOR, durante a pandemia da COVID-19, em agosto de 2020. Como parâmetro, foi aplicada a Escala Verbal de Dor para 20 pacientes referente ao pré-operatório, intra-operatório e no pós-operatório. Resultados: Os pacientes não sentiram nenhuma dor durante a cirurgia, tendo a técnica anestésica de mostrado eficaz. Conclusão: Pelas análises, foi possível considerar segura e benéfica a técnica WALANT diante da pandemia da COVID-19, que apresenta o diferencial de ser aplicada por um cirurgião ortopédico especialista em mão bem treinado. Nível de Evidência IV, Série de Casos.

7.
J Wrist Surg ; 8(2): 147-151, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30941256

RESUMEN

Background This article measures the life quality, clinical, and functional outcomes of a patient who had undergone reconstruction of the radioscaphocapitate ligament (RSL), using brachioradialis tendon in the treatment of ulnar translation of the carpus. Case Description We present a 36-year-old man with ulnar translation in his left, nondominant wrist, after fall accident. Reconstruction of the RSL was performed. One year later, the patient experienced good evaluation. Wrist flexion was 70 degrees, extension was 60 degrees, radial deviation was 20 degrees, and ulnar deviation was 30 degrees. Forearm pronation was 85 degrees and supination was 90 degrees and digit motion was full. Disabilities of the Arm, Shoulder and Hand score of 5, Visual Analog Scale of 0, and grip strength of 82% were obtained compared with the unaffected side. Wrist radiographic aspects showed radiocarpal joint congruency. The period of fixator treatment was 8 weeks. Good stability and joint congruency of the radiocarpal joint were obtained. Good radiographic, clinical, and functional results were obtained improving the quality of life of the patient. Literature Review The treatment of ulnar translation is difficult and complicated. There is no consensus to the overall management. As there is still a lack of long-term results, the indications for surgery, various surgical options, and the type of intervention have been a matter of controversy in the literature. Would radiocarpal joint be stable when reconstruction of the RSL using brachioradialis tendon was obtained? Is it possible to reduce an ulnar translation with this technique? Clinical Relevance We would like to suggest that the radiocarpal ligament reconstruction will improve the outcome. We believe that this technique will make the wrist more stable and functional. We agree that the best time to perform the corrections is early. The authors prefer to first reconstruct the RSL and then the radiocarpal ligament suture or radioscapholunate arthrodesis.

8.
Rev Bras Ortop ; 51(4): 431-6, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27517022

RESUMEN

OBJECTIVE: To present the clinical and functional results, including measurement of quality of life, of patients undergoing trapeziometacarpal arthroplasty. METHOD: This was a prospective evaluation on 45 patients (53 thumbs) with a diagnosis of idiopathic rhizarthrosis who underwent resection arthroplasty and interposition of an uncemented Ascension(®) implant, made of pyrocarbon. The clinical and functional results were analyzed through radiography, range of motion (ROM) in degrees (°), visual analog scale (VAS) for pain and the disability of arm, shoulder and hand (DASH) questionnaire for quality of life. In the group analyzed, 38 were women and seven were men, and their mean age was 63.17 years (range: 50-78). Eight patients were treated bilaterally. RESULTS: After 42.08 months of follow-up (range: 8-73), the subjective pain evaluation (VAS) score was 1.37 (range: 1-4). The complete ROM of the thumb increased to 95.75% (range: 75-100%) in relation to the contralateral side. The mean DASH questionnaire score was 9.98 (range: 1-18). The complication rate (negative events) was 11.32%. Five patients presented dislocation of the thumb prosthesis. All of them were reoperated by means of dorsal capsuloplasty using a portion of the retinaculum of the extensors as a graft, and good clinical evolution was achieved in these cases. One patient presented fracturing of the metacarpal and was treated by means of osteosynthesis using Kirschner wires. CONCLUSION: This method is effective for treating rhizarthrosis, according to the measurements made on the clinical and functional results, even after taking the complication rate into consideration. Moreover, it provides an improvement of quality of life for these patients.


OBJETIVO: Apresentar os resultados clínico-funcionais e a mensuração da qualidade de vida dos pacientes submetidos à artroplastia trapézio-metacárpica. MÉTODO: Avaliação prospectiva de 45 pacientes e 53 polegares acometidos, com diagnóstico de rizartrose idiopática submetidos à artroplastia de ressecção e interposição, com o implante Ascension®, não cimentado, de pirocarbono. Foram analisados os resultados clínico-funcionais: análise radiográfica, o arco de movimento (ADM) em graus (°), dor (VAS: visual analog score), qualidade de vida (Dash: disability shoulder, arm, and hand questionnaire). No grupo analisado, 38 são mulheres e sete são homens e a idade média é de 63,17 anos (50-78). Foram operados oito pacientes com acometimento bilateral dos polegares. RESULTADOS: Após 42,08 meses (8-73) de seguimento, a avaliação subjetiva da dor (VAS) foi de 1,37 (1-4). O arco do movimento completo do polegar teve um aumento de 95,75% (75-100) do lado contralateral. O questionário Dash foi em média de 9,98 (1-18). A taxa de complicações ou eventos negativos foi de 11,32%. Observamos cinco pacientes com luxações das próteses de polegares. Todos foram reoperados e fez-se a capsuloplastia dorsal, com o uso como enxerto de uma porção da retinácula dos extensores, obteve-se uma boa evolução clínica nesses casos. Um paciente apresentou fratura do metacarpo e foi tratado com osteossíntese com fio de Kirschner. CONCLUSÃO: O método é eficaz no tratamento da rizartrose de acordo com os valores apurados dos resultados clínico-funcionais, mesmo considerando-se as taxas de complicações. Além disso, proporciona a melhoria da qualidade de vida desses pacientes.

9.
Rev. bras. ortop ; 51(4): 431-436, July-Aug. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-792726

RESUMEN

ABSTRACT OBJECTIVE: To present the clinical and functional results, including measurement of quality of life, of patients undergoing trapeziometacarpal arthroplasty. METHOD: This was a prospective evaluation on 45 patients (53 thumbs) with a diagnosis of idiopathic rhizarthrosis who underwent resection arthroplasty and interposition of an uncemented Ascension(r) implant, made of pyrocarbon. The clinical and functional results were analyzed through radiography, range of motion (ROM) in degrees (°), visual analog scale (VAS) for pain and the disability of arm, shoulder and hand (DASH) questionnaire for quality of life. In the group analyzed, 38 were women and seven were men, and their mean age was 63.17 years (range: 50-78). Eight patients were treated bilaterally. RESULTS: After 42.08 months of follow-up (range: 8-73), the subjective pain evaluation (VAS) score was 1.37 (range: 1-4). The complete ROM of the thumb increased to 95.75% (range: 75-100%) in relation to the contralateral side. The mean DASH questionnaire score was 9.98 (range: 1-18). The complication rate (negative events) was 11.32%. Five patients presented dislocation of the thumb prosthesis. All of them were reoperated by means of dorsal capsuloplasty using a portion of the retinaculum of the extensors as a graft, and good clinical evolution was achieved in these cases. One patient presented fracturing of the metacarpal and was treated by means of osteosynthesis using Kirschner wires. CONCLUSION: This method is effective for treating rhizarthrosis, according to the measurements made on the clinical and functional results, even after taking the complication rate into consideration. Moreover, it provides an improvement of quality of life for these patients.


RESUMO OBJETIVO: Apresentar os resultados clínico-funcionais e a mensuração da qualidade de vida dos pacientes submetidos à artroplastia trapézio-metacárpica. MÉTODO: Avaliação prospectiva de 45 pacientes e 53 polegares acometidos, com diagnóstico de rizartrose idiopática submetidos à artroplastia de ressecção e interposição, com o implante Ascension(r), não cimentado, de pirocarbono. Foram analisados os resultados clínico-funcionais: análise radiográfica, o arco de movimento (ADM) em graus (°), dor (VAS: visual analogue score), qualidade de vida (Dash: disability shoulder, arm, and hand questionnaire). No grupo analisado, 38 são mulheres e sete são homens e a idade média é de 63,17 anos (50-78). Foram operados oito pacientes com acometimento bilateral dos polegares. RESULTADOS: Após 42,08 meses (8-73) de seguimento, a avaliação subjetiva da dor (VAS) foi de 1,37 (1-4). O arco do movimento completo do polegar teve um aumento de 95,75% (75-100) do lado contralateral. O questionário Dash foi em média de 9,98 (1-18). A taxa de complicações ou eventos negativos foi de 11,32%. Observamos cinco pacientes com luxações das próteses de polegares. Todos foram reoperados e fez-se a capsuloplastia dorsal, com o uso como enxerto de uma porção da retinácula dos extensores, obteve-se uma boa evolução clínica nesses casos. Um paciente apresentou fratura do metacarpo e foi tratado com osteossíntese com fio de Kirschner. CONCLUSÃO: O método é eficaz no tratamento da rizartrose de acordo com os valores apurados dos resultados clínico-funcionais, mesmo considerando-se as taxas de complicações. Além disso, proporciona a melhoria da qualidade de vida desses pacientes.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Artroplastia , Calidad de Vida , Pulgar , Hueso Trapecio
10.
Rev Bras Ortop ; 51(1): 16-23, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26962488

RESUMEN

OBJECTIVE: To analyze the clinical-functional parameters and quality of life of patients undergoing minimally invasive surgical treatment for extra-articular fractures of the proximal phalanx, using an intramedullary screw (Acutrak(®)). METHODS: Between January 2011 and September 2014, a prospective study was conducted on 41 patients (48 fingers) with unstable extra-articular fractures of the proximal phalanx, who underwent minimally invasive surgical treatment using an intramedullary screw (Acutrak(®)). These patients were evaluated 12 months after the surgery by means of the DASH quality-of-life questionnaire, VAS pain scale, measurement of range of motion (ROM, in degrees) and radiographic assessment. RESULTS: All the patients achieved adequate reduction and consolidation of their fractures. There were statistically significant improvements in quality of life on the DASH scale, pain on the VAS scale and range of motion. CONCLUSION: The minimally invasive technique for treating unstable extra-articular fractures of the proximal phalanx using an intramedullary screw (Acutrak(®)) is effective and safe, and it presents satisfactory clinical-functional results.


OBJETIVO: Analisar os parâmetros clínico-funcionais e a qualidade de vida de pacientes submetidos ao tratamento cirúrgico minimamente invasivo das fraturas extra-articulares da falange proximal com uso do parafuso intramedular (Acutrak®). MÉTODOS: Um estudo prospectivo foi feito de janeiro de 2011 a setembro de 2014 e incluiu 41 pacientes e 48 dedos acometidos com fratura da falange proximal extra-articular e instável submetidos ao tratamento cirúrgico minimamente invasivo com parafuso intramedular (Acutrak®). Esses pacientes foram avaliados 12 meses após a cirurgia por meio do questionário DASH de qualidade de vida, escala de dor VAS, arco de movimento (adm em graus) e avaliação radiográfica. RESULTADOS: Todos os pacientes obtiveram redução adequada e consolidação das fraturas. Houve melhoria estatisticamente significativa da qualidade de vida (DASH), escala de dor (VAS) e arco de movimento. CONCLUSÃO: A técnica minimamente invasiva no tratamento das fraturas instáveis e extra-articulares da falange proximal com o parafuso intramedular Acutrak® é eficaz e segura e apresenta resultados clínico-funcionais satisfatórios.

11.
Rev. bras. ortop ; 51(1): 16-23, Jan.-Feb. 2016. tab, graf
Artículo en Portugués | LILACS | ID: lil-775657

RESUMEN

To analyze the clinical-functional parameters and quality of life of patients undergoing minimally invasive surgical treatment for extra-articular fractures of the proximal phalanx, using an intramedullary screw (Acutrak(r)). METHODS: Between January 2011 and September 2014, a prospective study was conducted on 41 patients (48 fingers) with unstable extra-articular fractures of the proximal phalanx, who underwent minimally invasive surgical treatment using an intramedullary screw (Acutrak(r)). These patients were evaluated 12 months after the surgery by means of the DASH quality-of-life questionnaire, VAS pain scale, measurement of range of motion (ROM, in degrees) and radiographic assessment. RESULTS: All the patients achieved adequate reduction and consolidation of their fractures. There were statistically significant improvements in quality of life on the DASH scale, pain on the VAS scale and range of motion. CONCLUSION: The minimally invasive technique for treating unstable extra-articular fractures of the proximal phalanx using an intramedullary screw (Acutrak(r)) is effective and safe, and it presents satisfactory clinical-functional results.


Analisar os parâmetros clínico-funcionais e a qualidade de vida de pacientes submetidos ao tratamento cirúrgico minimamente invasivo das fraturas extra-articulares da falange proximal com uso do parafuso intramedular (Acutrak(r)). MÉTODOS: Um estudo prospectivo foi feito de janeiro de 2011 a setembro de 2014 e incluiu 41 pacientes e 48 dedos acometidos com fratura da falange proximal extra- articular e instável submetidos ao tratamento cirúrgico minimamente invasivo com parafuso intramedular (Acutrak(r)). Esses pacientes foram avaliados 12 meses após a cirurgia por meio do questionário DASH de qualidade de vida, escala de dor VAS, arco de movimento (adm em graus) e avaliação radiográfica. RESULTADOS: Todos os pacientes obtiveram redução adequada e consolidação das fraturas. Houve melhoria estatisticamente significativa da qualidade de vida (DASH), escala de dor (VAS) e arco de movimento. CONCLUSÃO: A técnica minimamente invasiva no tratamento das fraturas instáveis e extra-articulares da falange proximal com o parafuso intramedular Acutrak(r) é eficaz e segura e apresenta resultados clínico-funcionais satisfatórios.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Fijación de Fractura , Fijación Interna de Fracturas , Falanges de los Dedos de la Mano/cirugía , Falanges de los Dedos de la Mano/lesiones
12.
Rev. bras. ortop ; 50(6): 666-672, Nov.-Dec. 2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-769990

RESUMEN

To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r) prosthesis of the distal ulna.METHODS:Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex) and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale); percentage degree of palm grip strength (kgf) and pronosupination range of motion in relation to the unaffected side; pain (VAS); return to work; subjective evaluation of radiography; and complications...


Mensurar a qualidade de vida e os resultados clínico-funcionais dos pacientes com diagnóstico de osteoartrose da radioulnar distal submetidos ao tratamento cirúrgico pela técnica de artroplastia total da ulna com a prótese total ou parcial Ascension(r)da ulna distal. MÉTODOS: Foram avaliados 10 pacientes com 12 meses de seguimento de artroplastia total ou parcial de ulna distal. Todos apresentavam osteoartrose pós-traumática e ou instabilidade crônica e sintomática da articulação radioulnar distal. O estudo foi prospectivo. Sete pacientes tinham procedimentos prévios no punho (2-darrach, 3-Sauvé-kapandji, 2-reconstruções ligamentares do complexo da fibrocartilagem) e três apresentaram fraturas da ulna distal que evoluíram com dor, instabilidade e osteoartrose da radioulnar distal. Foram analisados a qualidade de vida (DASH), a porcentagem do grau de força de preensão palmar (kgf) e o arco de movimento de pronossupinação em relação ao lado não afetado, a dor (VAS), o retorno ao trabalho e a avaliação subjetiva da radiografia e das complicações...


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Prótesis Articulares , Fracturas del Radio , Fracturas del Cúbito
13.
Rev Bras Ortop ; 50(6): 666-72, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27218078

RESUMEN

OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(®) prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex) and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale); percentage degree of palm grip strength (kgf) and pronosupination range of motion in relation to the unaffected side; pain (VAS); return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°). Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf) was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time. Implantation of a prosthesis is a very interesting addition to the surgical arsenal for those who are specialists in hand surgery. Arthroplasty of the distal ulna is a safe and effective method with clinical-functional and quality-of-life improvements for patients and presents a low complication rate.


OBJETIVO: Mensurar a qualidade de vida e os resultados clínico-funcionais dos pacientes com diagnóstico de osteoartrose da radioulnar distal submetidos ao tratamento cirúrgico pela técnica de artroplastia total da ulna com a prótese total ou parcial Ascension® da ulna distal. MÉTODOS: Foram avaliados 10 pacientes com 12 meses de seguimento de artroplastia total ou parcial de ulna distal. Todos apresentavam osteoartrose pós-traumática e ou instabilidade crônica e sintomática da articulação radioulnar distal. O estudo foi prospectivo. Sete pacientes tinham procedimentos prévios no punho (2-darrach, 3-Sauvé-kapandji, 2-reconstruções ligamentares do complexo da fibrocartilagem) e três apresentaram fraturas da ulna distal que evoluíram com dor, instabilidade e osteoartrose da radioulnar distal. Foram analisados a qualidade de vida (DASH), a porcentagem do grau de força de preensão palmar (kgf) e o arco de movimento de pronossupinação em relação ao lado não afetado, a dor (VAS), o retorno ao trabalho e a avaliação subjetiva da radiografia e das complicações. RESULTADOS: Os pacientes apresentaram, em média, o arco de movimento de 174,5° e o lado normal 180°. A qualidade de vida foi analisada pela aplicação do questionário DASH e o valor médio encontrado foi 5,9. A avaliação da dor, com o uso da escala VAS, foi de 2,3, em média. O grau de força de preensão palmar (kgf) foi de 50,7, em média, o que representa 90,7% da força do lado não acometido. A taxa de complicações foi de 10%. Esse paciente apresentou discreta instabilidade dorsal da ulna, dor persistente e não retornou ao trabalho. Esse paciente segue no ambulatório e no setor de terapia ocupacional, com pouca melhoria. Não deseja fazer novo procedimento. O tempo de seguimento, em média, foi de 16,8 meses, com mínimo de 10 e máximo de 36 meses. CONCLUSÃO: Esse conceito está a teste do tempo. A implantação de uma prótese é uma adição muito interessante ao arsenal cirúrgico para aqueles que são especializados em cirurgia da mão. A artroplastia de ulna distal é um método seguro, eficaz, com melhoria clínico-funcional e da qualidade de vida dos pacientes e apresenta baixo índice de complicações.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...